Chauffage soufflant industriel CAT 3KW pour conteneurs isolés

Chauffage soufflant industriel CAT 3KW pour conteneurs isolés

(16)

Reference : MGA54I4

from €650

In stock

3 kW industrial fan heater designed for insulated containers. White RAL 9016 powder-coated galvanized steel housing, IP44 protection, +5 °C to +30 °C regulation. Ideal for maintaining comfortable temperatures in fitted-out containers (offices, workshops, storage) and withstands outdoor environments.

1

Brand: D.S. Globe Conteneur

Returns within 30 days, subject to exceptions for customised products. The customer arranges and pays for return transport after contacting customer service.

Delivery and return terms

Specifications

Puissance
3 kW
Tension d'alimentation
230 V monophasé
Plage de régulation de température
+5 °C à +30 °C
Élévation de température de l'air soufflé
+32 °C
Débit d'air
280 m³/h
Indice de protection
IP44
Dimensions extérieures (L × P × H)
335 × 276 × 255 mm
Matériau du boîtier
Acier galvanisé, revêtement thermolaqué
Couleur
Blanc RAL 9016
Fabricant
PROTECTO
Référence fabricant
23569
Poids propre
Non spécifié

Description

The CAT 3KW industrial fan heater is an electric heating unit designed for installation in insulated shipping containers. It maintains an indoor temperature between +5 °C and +30 °C, making it suitable for both heating workspaces and frost protection of sensitive stored goods. Its robust design with a galvanized steel housing and white RAL 9016 powder coating provides good resistance to corrosion and outdoor environments. With 3 kW output and 230 V single-phase power, it offers a self-contained and efficient heating solution for properly insulated 20-foot or 40-foot containers. Technical specifications and performance This fan heater operates on the forced convection principle: an electric heating element warms the air, which is then distributed by a fan. This technology enables rapid temperature rise and even heat distribution throughout the container volume. The +5 °C to +30 °C control range suits common needs: frost protection, supplementary heating for a site office, workshop or technical room. The temperature rise of the supply air is +32 °C, meaning the discharged air is significantly warmer than the ambient air, ensuring efficient heating even in cold weather. The 280 m³/h air flow allows a large volume of air to be circulated, promoting rapid heat diffusion. The IP44 protection rating ensures protection against water splashes and solid objects larger than 1 mm, allowing outdoor or damp environment use, provided the unit is not directly exposed to rain. The 230 V single-phase supply voltage is standard and does not require a three-phase installation, simplifying electrical connection. The 3 kW output corresponds to a current of approximately 13 A; a dedicated electrical line with a suitable circuit breaker and sufficient cable cross-section is therefore recommended to prevent overheating. The manufacturer PROTECTO, reference 23569, specializes in heating and ventilation equipment for technical applications. Construction and durability The housing is made of galvanized steel, a material that offers excellent corrosion resistance. The white RAL 9016 powder coating provides a neat finish and additional protection against outdoor exposure. This construction is designed for industrial and outdoor use, meaning the unit can withstand site conditions or installation in a container exposed to the elements. The external dimensions of 335 × 276 × 255 mm (length × depth × height) make it a compact unit that can be wall-mounted or floor-standing without taking up excessive space. Its own weight is not specified, but it remains light enough to be handled by one person during installation. The white RAL 9016 color blends with many interior layouts and facilitates integration into a container converted into an office or living space. Typical uses in insulated containers Insulated shipping containers are often used as site offices, welfare units, workshops, storage rooms or temporary commercial spaces. The CAT 3KW fan heater is particularly suited to these applications. In a properly insulated 20-foot container (approximately 14 m² floor area), 3 kW output maintains a comfortable temperature even when the outdoor temperature drops below 0 °C. For a 40-foot container (approximately 28 m²), it can be used alongside another unit or to maintain a moderate temperature. In winter, heating containers is essential to prevent pipes and stored products from freezing or to ensure occupant comfort. This heater can also be used in refrigerated containers (reefers) when out of service, or in open top or flat rack containers temporarily fitted out. Its IP44 rating makes it suitable for use in dusty or damp environments such as construction sites, ports or industrial areas. It can also be used in containers intended for modular housing, as a supplement to a main heating system or for rapid supplementary heating. Installation and setup Installation of the CAT 3KW fan heater must be carried out by a qualified electrical professional. It is important to follow the manufacturer's instructions and applicable standards (NF C 15-100 for electrical installations). The unit must be mounted on a stable surface, protected from impacts and direct water splashes. A dedicated power supply with a residual current device and a circuit breaker rated for the nominal current is recommended. Cable cross-section must be calculated based on line length and unit power to prevent voltage drops and overheating. Clearance should be provided around the unit to allow proper air circulation and prevent overheating. The built-in thermostat regulates ambient temperature; it is recommended to position it away from direct heat sources for reliable measurement. Finally, regular maintenance (cleaning grilles, checking electrical connections) will extend the unit's service life. Points to consider when purchasing When purchasing a container heater, several criteria must be taken into account. The output must match the volume to be heated and the container's insulation level. An uninsulated container will require higher output or additional insulation. The supply voltage must match the installation available on site: 230 V single-phase is common, but some industrial sites have 400 V three-phase. In that case, a three-phase model may be preferred. The IP protection rating is crucial for outdoor or damp environment use: IP44 is a minimum, but IP55 or IP65 may be required in highly exposed environments. Build quality (galvanized steel, powder coating) ensures durability. Finally, spare parts availability and the manufacturer's after-sales service are factors to consider. It is also important to verify the unit's compliance with European standards (CE marking) and safety requirements (overheat protection, automatic shut-off if tipped over, etc.). Regulations and transport In France, installing an electric heater must comply with standard NF C 15-100. For containers used as workspaces, the Labor Code sets temperature requirements (generally 19 °C for sedentary work) and air renewal requirements. The employer must ensure installations are compliant and maintained. If the container is intended for habitation, specific rules apply (aeration, ventilation, fire safety). Transporting a container equipped with a heater must be done with the unit securely fastened and disconnected. For sea freight, it is advisable to remove the unit or protect it against moisture and vibration. The container itself must comply with ISO 668 and 1496 standards for transport, but this does not directly concern the heater. For installation in a container, adequate ventilation should be provided to prevent condensation, and suitable insulation materials (mineral wool, polyurethane foam) should be used to optimize heater efficiency. Care and maintenance To ensure optimal and long-lasting operation, regular maintenance is necessary. Air inlet and outlet grilles should be cleaned to prevent dust accumulation, which can reduce air flow and cause overheating. Electrical connections and the power cord should be checked periodically by a professional. In case of malfunction, contact the manufacturer or an approved repairer. Wearing parts (heating element, fan) must be replaced with original parts. A function test before each cold season is recommended. Finally, when storing the unit, protect it from moisture and impacts. Sector-specific use cases In the construction sector, this heater is used in welfare units and site offices installed in containers. It allows work to be carried out under acceptable conditions during winter months, contributing to compliance with employer health and safety obligations. Site containers are often moved; a compact and robust heater like this is therefore particularly suitable. In industry, it can heat technical workshops, control rooms or maintenance rooms. Its IP44 protection makes it suitable for use in environments where moisture and dust are present. For storage, it is used to keep sensitive products frost-free (paints, adhesives, chemicals, non-perishable foodstuffs). In the events sector, it can equip containers used as dressing rooms, control booths or temporary reception areas. Finally, in modular housing, it provides a supplementary heating solution for containers fitted out as temporary accommodation, as a complement to a main system or for emergency backup. Comparison with other heater sizes and types The CAT 3KW sits in the range of small to medium-power industrial fan heaters. For a well-insulated 20-foot container, 3 kW is generally sufficient. For a 40-foot container, two 3 kW units or a higher-output model (5 kW, 9 kW or more) may be necessary. Higher-output heaters are often three-phase and require a suitable electrical installation. The choice between a fan heater and a radiant heater depends on use: fan heaters warm the air and suit continuously occupied spaces, while radiant heaters warm people and objects, and are better suited to large volumes or poorly insulated areas. Fuel heaters (gas, oil) offer energy independence but require flue exhaust and ventilation, making them less simple to install in a container. Electric inertia heaters (radiators) are silent but heat up more slowly. The CAT 3KW offers a good compromise between heating speed, compactness and ease of installation. Finally, there are specific heaters for reefer containers that use the existing refrigeration unit; the CAT 3KW can be an alternative when the refrigeration unit is out of service. Precautions for use and safety Like any electric heater, the CAT 3KW must be used in accordance with its instructions. It must not be covered, obstructed or placed near flammable materials. A safety distance must be maintained around the unit. It should not be used in an explosive atmosphere or in the presence of combustible dust. The unit must not be exposed to direct water splashes, despite its IP44 rating. If a burning smell or malfunction occurs, immediately disconnect the power and have the unit checked. Use of an extension cord is not recommended; it is preferable to connect the unit directly to a suitable wall outlet. Finally, it is important to verify that the unit's power is compatible with the electrical installation of the container or site. Optimizing energy efficiency To get the most out of this heater in a container, proper thermal insulation is essential. A standard shipping container is made of Corten steel, a conductive material that promotes heat loss. Adding internal insulation (mineral wool panels, polyurethane foam, extruded polystyrene) can significantly reduce heating requirements. It is also recommended to address thermal bridges, particularly at uprights and cross members, and to ensure proper air tightness (door seals, cable passages). Controlled ventilation is necessary to remove moisture and prevent condensation, but it must be moderate to avoid excessively cooling the space. Using a programmable thermostat or a controller with time scheduling allows heating only when needed, reducing power consumption. Finally, unit positioning should promote even air circulation: avoid placing it behind an obstacle and direct the air flow toward the area to be heated. These best practices help maintain satisfactory thermal comfort while limiting installed power. Conclusion The CAT 3KW industrial fan heater is a reliable and robust solution for heating insulated containers. Its powder-coated galvanized steel construction, IP44 protection rating and wide control range make it a versatile piece of equipment suited to industrial and outdoor environments. It meets the heating needs of site offices, workshops, storage rooms and modular housing. By following installation and maintenance rules, it provides an efficient and durable heating solution for your containers.

Customer reviews

4.6/ 5

Based on 16

Correct sans plus

Le chauffage fonctionne, mais je m'attendais à mieux. Il chauffe correctement un petit conteneur, mais pour un plus grand, il faut du temps. Le thermostat est basique. Pour le prix, je pensais avoir plus de fonctionnalités. Ça reste correct.

Romain P.✓ Verified purchase

Chauffage efficace et robuste

Après deux mois d'utilisation dans un conteneur de stockage pour mes outils agricoles, aucun problème. Le boîtier en acier galvanisé est solide, la peinture blanche ne s'écaille pas malgré l'humidité. Il chauffe vite et le thermostat est fiable. Je l'ai mis à 10°C pour éviter le gel, et ça fonctionne nickel. Un bon rapport qualité-prix.

Fabien S.✓ Verified purchase

Bien mais un peu bruyant

Le chauffage fait le job, mais je le trouve un peu bruyant quand il est en marche. Dans un atelier, ça passe, mais dans un bureau, c'est moins agréable. Sinon, il chauffe bien et la régulation est précise. Je mets 4 étoiles à cause du bruit.

Delphine M.✓ Verified purchase